| Conductors: | 24 AWG Bare Copper |
|
|||||
| Insulation: | Polyethylene (Non-Plenum) and FEP (Plenum) | ||||||
| Jacket: | PVC (Non-Plenum) or Low Smoke (Plenum) | ||||||
| Jacket Color: | Blue and Gray (Other colors available - contact factory) |
||||||
| Color Code: | #12 | ||||||
| Electricals: |
|
||||||
| To
view an Adobe Acrobat PDF specification, click on the PDF symbol ( Click here to download a copy of Adobe Acrobat. |
|||||||||
| Part No. |
No.of Pairs |
AWG Size |
(Nom) Conductor Diameter |
(Nom) Insulation Thickness |
(Nom) Jacket Thickness |
Nom. O.D. |
Wt. per 1000' |
UL Type Listed |
|
| 96263 Non-Plenum |
4 | 24 | .0201 | .009 | 0.020 | 0.220 | 20 | CMR/MPR C(UL) FT4 |
|
| 966956 Plenum |
4 | 24 | .0201 | .007 | 0.015 | 0.180 | 20 | CMP/MPP C(UL) FT6 |
|
| UL
or ETL verified to TIA/EIA-568A. Exceeds:TIA-EIA-568-A, UL 1666, (CMR),
UL 910 (CMP) Applications: Gigabit Ethernet 100 Base T Broad Band Video 155 Mbs ATM Fast Ethernet T1 ISDN 622 Mbps ATM Systems Approvals: Our Category 5 Cables carry many systems approvals in addition to our 15 year Limited Warranty. Call you local agent or the factory for current listings. |
|||||||||